Free hot line
8-800-2008-078
only for domestic calls
Gas heating facility «Lemax» series «Premier»
Gas heating facility «Lemax» series «Premier»
Gas heating facility «Lemax» series «Premier»
Gas heating facility «Lemax» series «Premier»
Gas heating facility «Lemax» series «Premier»
Gas heating facility «Lemax» series «Premier»
Gas heating facility «Lemax» series «Premier»
Gas heating facility «Lemax» series «Premier»
  • The cylindrical form of the heat exchanger allows the facility to operate in closed systems (from 17.4 kw)
  • “CERTA” anticorrosive enameled coating of heat exchanger having an exposure temperature of 750 ° C, and treatment of the heat exchanger with an inhibitory composition protect it against aggressive factors: solutions of salts, mineral oils during storage and transportation
  • Maximum operating pressure is 3 bar (with 17.4 kw)
  • The facility is made of high-quality steel corresponding to the brand DC01 of EN 10130: 2006
  • The expanded production range of facilities with capacity from 11,6 to 35 kw
  • Does not require an electrical connection
  • Equipped exclusively with the original components of the gas burner and the gas valve 820 Nova of the Italian concern SIT, and the injection microflame burner “POLIDORO”
  • The temperature control is delivered to the front panel, which allows you to select the optimal thermal mode
  • Smooth-start system
  • Protection against overheating, traction interruption, soot formation, and blowing of the boiler.
  • Vertical and horizontal connection of the chimney
  • Convenient cleaning of the facility without detaching from the chimney due to the use of removable lining covers and weight stabilizer
  • Advanced safety protection system using a heat exchanger overheating sensor
  • The maximum efficiency due to
    • increased heat exchange area
    • modification of turbulizer design for maximum exhaust gas retention
  • Increase in primary and secondary air inflows
  • Possibility to connect external fan «Lemax» series «Comfort»
  • Possibility to connect a room thermostat, by means of which it is possible to regulate the boiler temperature with respect to the temperature inside the room
  • The possibility of switching to liquefied gas

 

CERTIFICATE (PDF)   PASSPORT (PDF)


Наименование параметров
Premier 11,6Premier 17,4Premier 23,2Premier 29Premier 35
Nominal heat power, kW 11,6 17,4 23,2 29 35
Energy conversion efficiency, % not less than 90 90 90 90 90
Номинальное давление газа, Па 1300 1300 1300 1300 1300
Average gas flow, m3/hr          
- maximum 1,16 1,74 2,32 2,9 3,5
- avarage 0,6 0,9 1,2 1,5 1,75
Gas nominal pressure, mmWC  0,1  0,3  0,3  0,3  0,3
The range of discharge which ensures stable operation of the boiler, Pa 3-29 3-29 3-29 3-29 3-29
Flue-gas temperature °С, not less than 110 110 110 110 110
Fitting nipple diameter 1½’’ 2’’ 2’’ 2’’ 2’’
Gas nipple diameter ½’’ ¾’’ ¾’’ ¾’’ ¾’’
Outer diameter of gas bleeding branch pipe, mm 120 130 140 140 140
Maximum heating medium temperature at the facility exit, °С 90 90 90 90 90
Dimensions, mm:          
- height 835 865 1065 1065 1065
- width 325 415 465 465 465
- depth 570 615 690 690 690
Weight, kg not more than 41,5 60 76 79 79