Comfort Series (models M, L, L140, XL, XXL). The devices are designed for volatile boilers of the CLEVER and WISE series, equipped with the SIT 845 SIGMA safety automatics. The scope of delivery of the equipment includes a turbo nozzle, a connection cable, an instruction manual and a cardboard box.
Comfort SE Series (models S, M, L, L140, XL, XXL). Turbo nozzles work in tandem with non-volatile boilers equipped with SIT 820 NOVA automatics. The devices are compatible with models of the Prestige, UNO, Classic 35-40 kW, Premium N, as well as gas heating devices of the Premier series. The delivery set, in addition to the turbo nozzle itself, includes a ground wire, an equipment control unit, an operating manual, a connection diagram and a packing container.
Comfort SE Series (models S, M, L, L140, XL, XXL). Turbo nozzles work in tandem with non-volatile boilers equipped with SIT 820 NOVA automatics. The devices are compatible with models of the Prestige, UNO, Classic 35-40 kW, Premium N, as well as gas heating devices of the Premier series. The delivery set, in addition to the turbo nozzle itself, includes a ground wire, an equipment control unit, an operating manual, a connection diagram and a packing container.
Type of heat exchanger | Steel heat exchanger | Cast-iron heat exchanger | ||||||||
---|---|---|---|---|---|---|---|---|---|---|
Nominal boiler heat output, kW |
from 7,5 to 10 kW |
from 12,5 to 16 kW |
from 20 to 30 kW |
from 35 to 40 kW |
50 kW | 60 kW | 16 kW | 25 kW | 35 kW | 40 kW |
Energy-independent boiler | model Comfort SE (S) | model Comfort SE (M) | model Comfort SE (L) | model Comfort SE (L 140) | model Comfort SE (XL) | model Comfort SE (XXL) | model Comfort SE (L) | model Comfort SE (L) | model Comfort SE (L 140) | model Comfort SE (L 140) |
Energy-dependent boiler | model Comfort S(C) | model Comfort M(C) | model Comfort L(C) | model Comfort L(140C) | model Comfort (XL) | model Comfort (XXL) | model Comfort L(C) | model Comfort L(C) | model Comfort L(140C) | model Comfort L(140C) |
Underpressure, caused by turbo-extraction (at boiler exit), Pa | 5-8 | 5-12 | 5-12 | 5-12 | 5 | 5 | 5-12 | 5-12 | 5-12 | 5-12 |
Pressure at extraction exit, Pa | 40-70 | 40-70 | 40-70 | 40-70 | not more than 22 | not more than 22 | 40-70 | 40-70 | 40-70 | 40-70 |
Flue diameter, mm | 100 | 130 | 130 | 140 | 200 | 200 | 130 | 130 | 140 | 140 |
Diameter of outlet connection, mm | 80 | 80 | 80 | 80 | 100 | 100 | 80 | 80 | 80 | 80 |
Diameter of choke ring of outlet connection, mm | - | - | - | - | - | - | 39 | 47 | 49 | - |
System nominal voltage, V | 230 | 230 | 230 | 230 | 230 | 230 | 230 | 230 | 230 | 230 |
Rated current frequency, Hz | 50 | 50 | 50 | 50 | 50 | 50 | 50 | 50 | 50 | 50 |
Noise level, dB not more than | 50 | 50 | 50 | 50 | 50 | 50 | 50 | 50 | 50 | 50 |
Consuming power, W not more than | 40 | 40 | 40 | 40 | 82 | 82 | 40 | 40 | 40 | 40 |
Mass, kg | 3,8 | 3,8 | 3,8 | 3,8 | 6,3 | 6,3 | 3,8 | 3,8 | 3,8 | 3,8 |