Boiler is made of 4 mm thick, high-quality gray cast iron produced by the VIADRUS company (Czech Republic). The heat exchanger is treated by inhibiting composition which prevents corrosion. The boiler doesn’t need to be plugged into an electric socket.
Separate sections are connected by means of the pressed nipples, pulled together with bolts and form the combustion chamber. The heat exchanger is characterized by heat resistance under high temperatures, high heat conductivity along with high efficiency which allows ranging it as advanced among its counterpart in the world.
Advantages of the gas boiler with gas valve 820 Nova SIT:
Parameter | Leader-16/ Leader-16N | Leader-25/ Leader-25N | Leader-35 | Leader-40 | Leader-50 |
---|---|---|---|---|---|
Type of gas burner unit | GGU 19 | GGU 30 | GGU 40 | GGU 45 | GGU 55 |
Rated heat output, kWh | 16 | 25 | 35 | 40 | 50 |
Capacity, no less than, % | 91 | 91 | 92 | 92 | 92 |
Indicated (rated) gas pressure , Pa | 1300 | 1300 | 1300 | 1300 | 1300 |
Average gas expenditure, m3 | 0,95 | 1,5 | 2 | 2,25 | 2,75 |
Maximum outlet water temperature,°С | 80 | 80 | 80 | 80 | 80 |
Chimney diameter, mm | 130 | 130 | 140 | 140 | 140 |
Gas pipe diameter, inches | 1/2" | 1/2" | 1/2" | 1/2" | 1/2" |
The diameter of the fitted pipes, inches | 1 1/2" | 1 1/2" | 1 1/2" | 1 1/2" | 1 1/2" |
Dimensions (height./width/depth) no more than, mm | 850/410/502 | 850/495/502 | 850/580/502 | 850/885/502 | 850/750/502 |
Mass, no more than , kg | 95 | 115 | 140 | 168 | 196 |