Parameter | CLEVER 20 | CLEVER 30 | CLEVER 40 | CLEVER 55 |
---|---|---|---|---|
Maximum heat capacity supply, kW |
Maximum heat capacity supply, kW
20
|
Maximum heat capacity supply, kW
30
|
Maximum heat capacity supply, kW
40
|
Maximum heat capacity supply, kW
55
|
Efficiency coefficiency, no less than, % |
Efficiency coefficiency, no less than, %
90
|
Efficiency coefficiency, no less than, %
90
|
Efficiency coefficiency, no less than, %
90
|
Efficiency coefficiency, no less than, %
90
|
Maximum service pressure in the heating system, MPa |
Maximum service pressure in the heating system, MPa
0,2
|
Maximum service pressure in the heating system, MPa
0,2
|
Maximum service pressure in the heating system, MPa
0,2
|
Maximum service pressure in the heating system, MPa
0,2
|
Heat-transfer fluid capacity in the heat exchanger, l |
Heat-transfer fluid capacity in the heat exchanger, l
43
|
Heat-transfer fluid capacity in the heat exchanger, l
41
|
Heat-transfer fluid capacity in the heat exchanger, l
62,5
|
Heat-transfer fluid capacity in the heat exchanger, l
66,5
|
Vacuum range, to provide safe boiler operating, Pa |
Vacuum range, to provide safe boiler operating, Pa
4-40
|
Vacuum range, to provide safe boiler operating, Pa
4-40
|
Vacuum range, to provide safe boiler operating, Pa
4-40
|
Vacuum range, to provide safe boiler operating, Pa
4-40
|
Average gas flow, m3/hr |
Average gas flow, m3/hr
1,25
|
Average gas flow, m3/hr
1,25
|
Average gas flow, m3/hr
2,25
|
Average gas flow, m3/hr
3,1
|
Outlet water maximum temperature, °С |
Outlet water maximum temperature, °С
90
|
Outlet water maximum temperature, °С
90
|
Outlet water maximum temperature, °С
90
|
Outlet water maximum temperature, °С
90
|
The diameter of the flue, mm |
The diameter of the flue, mm
130
|
The diameter of the flue, mm
130
|
The diameter of the flue, mm
140
|
The diameter of the flue, mm
150
|
Outlet combustion products temperature, not less than, °C |
Outlet combustion products temperature, not less than, °C
110
|
Outlet combustion products temperature, not less than, °C
110
|
Outlet combustion products temperature, not less than, °C
110
|
Outlet combustion products temperature, not less than, °C
110
|
Natural gas supply nominal pressure, Pa |
Natural gas supply nominal pressure, Pa
1300
|
Natural gas supply nominal pressure, Pa
1300
|
Natural gas supply nominal pressure, Pa
1300
|
Natural gas supply nominal pressure, Pa
1300
|
Power supply voltage, volt |
Power supply voltage, volt
220
|
Power supply voltage, volt
220
|
Power supply voltage, volt
220
|
Power supply voltage, volt
220
|
Network frequency, Hz |
Network frequency, Hz
50
|
Network frequency, Hz
50
|
Network frequency, Hz
50
|
Network frequency, Hz
50
|
Electric power, W: |
Electric power, W:
9
|
Electric power, W:
9
|
Electric power, W:
9
|
Electric power, W:
9
|
Mass net/gross, kg |
Mass net/gross, kg
80/85
|
Mass net/gross, kg
85/90
|
Mass net/gross, kg
110/116
|
Mass net/gross, kg
118/123
|
Dimensions, mm: | ||||
Height |
Height
961
|
Height
961
|
Height
1016
|
Height
1102
|
Width |
Width
470
|
Width
470
|
Width
532
|
Width
581
|
Depth |
Depth
556
|
Depth
556
|
Depth
608
|
Depth
656
|
Steel Gas Boilers of CLEVER Series
In accordance with European standard EN 10130: 2006, the American standard ASTM A 1011 and Russian GOST 16523-97 and GOST 9045-93 we use stainless steel 2mm thick grade DC01in production of Lemax boilers series CLEVER. The heat exchanger has a cylindrical shape, which allows the boiler to work in closed systems with the operating pressure of 2 atm. Due anticorrosive coating enamel (exposure temperature 950 °C) and treatment with inhibitory composition, the heat exchanger is protected from aggressive factors, solutions of salts and mineral oils.
Learn More
Description